• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sat, 11.05.24

Search results


March 2024
Batia Kaplan PhD, Rivka Goldis MSc, Tamar Ziv PhD, Amir Dori MD PhD, Hila Magen MD, Amos J Simon PhD, Alexander Volkov MD, Elad Maor MD PhD, Michael Arad MD

Background: Cardiac amyloidosis (CA) is characterized by the extracellular deposition of misfolded protein in the heart. Precise identification of the amyloid type is often challenging, but critical, since the treatment and prognosis depend on the disease form and the type of deposited amyloid. Coexistence of clinical conditions such as old age, monoclonal gammopathy, chronic inflammation, or peripheral neuropathy in a patient with cardiomyopathy creates a differential diagnosis between the major types of CA: amyloidosis light chains (AL), amyloidosis transthyretin (ATTR) and amyloidosis A (AA).

Objectives: To demonstrate the utility of the Western blotting (WB)-based amyloid typing method in patients diagnosed with cardiac amyloidosis where the type of amyloid was not obvious based on the clinical context.

Methods: Congo red positive endomyocardial biopsy specimens were studied in patients where the type of amyloid was uncertain. Amyloid proteins were extracted and identified by WB. Mass spectrometry (MS) of the electrophoretically resolved protein-in-gel bands was used for confirmation of WB data.

Results: WB analysis allowed differentiation between AL, AA, and ATTR in cardiac biopsies based on specific immunoreactivity of the electrophoretically separated proteins and their characteristic molecular weight. The obtained results were confirmed by MS.

Conclusions: WB-based amyloid typing method is cheaper and more readily available than the complex and expensive gold standard techniques such as MS analysis or immunoelectron microscopy. Notably, it is more sensitive and specific than the commonly used immunohistochemical techniques and may provide an accessible diagnostic service to patients with amyloidosis in Israel.

February 2014
Edward Koifman, Paul Fefer, Ilan Hay, Micha Feinberg, Elad Maor and Victor Guetta
Background: Percutaneous edge-to-edge mitral valve repair using the MitraClip® system has evolved as a new tool in the treatment of mitral regurgitation (MR).

Objectives: To present our initial experience with MitraClip implantation in 20 high risk patients at Sheba Medical Center.

Methods: Twenty high surgical risk patients with symptomatic significant MR underwent MitraClip implantation. Clinical and echocardiographic parameters were recorded at baseline and at follow-up.

Results: The patients’ mean age was 76 years and 65% were male. Coronary artery disease was present in 85% and 45% had previous bypass surgery. Renal failure was present in 65%, atrial fibrillation in 60%, and 30% had an implantable cardioverter defibrillator/cardiac resynchronization therapy device. Mean left ventricular ejection fraction was 36%. Grade III-IV MR was present in all patients with the vast majority suffering from functional MR secondary to ventricular remodeling. New York Heart Association (NYHA) class was III-IV in 90%. Patients were followed for a mean of 231 days. Acute reduction of MR grade to ≤ 2 was accomplished in 19 of the 20 patients (95%) with a 30 day mortality of 5%. At follow-up MR was reduced to ≤ 2 in 64% of patients, and NYHA class improved in 70% of patients. An additional 2 patients (11%) died during follow-up.

Conclusions: MitraClip implantation is feasible and safe in high risk highly symptomatic patients with significant MR. Acute and mid-term results are comparable to similar high risk patient cohorts in the literature. Continued surveillance and longer follow-up are needed to elucidate which patients are most likely to benefit from the procedure.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel